Capcalc
Capcalc software turns a Brookfield CAP2000+ Viscometer into an accurate rheometer for advanced sample analysis.
Your CAP2000+ Viscometer becomes a sensitive, accurate rheometer with Capcalc v3.0 Software! Capcalc allows control of the viscometer from a PC for automated testing, gathering and storing of test data. Built-in math models help to quickly and easily analyze material flow behavior.
-
FEATURES BENEFITS
Test Wizard allows for easy, automated data collection to eliminate operator error
BEAVIS commands — including Conditional Loop, Reporting Options, Data Averaging, and Set Spindle
Provides instantaneous viscosity flow curves (rheograms) on easy-to-read graphics
Records up to 1000 data points per test and creates a permanent test record in your choice of cP or mPas.
Plot up to four data sets simultaneously in 12 plot types
Yield stress calculations (Bingham Plastic, Casson, Power Law, Consistency Index)
On-line help system in English, Spanish and Japanese
Save data in text, Lotus 1-2-3- and Excel
The ability to communicate to more than four COM ports
Plot component with a second Y axis provides more plotting and display options, including online plotting during data collection
User-friendly interface with menus, toolbars and dockage control windows which can be resized and moved to create a custom display
- COMPUTER REQUIREMENTS
Windows 2000, XP, Vista, Windows 7, Windows 8, Windows 10
500 MHz processor
256 MB RAM
One RS-232 port
800×600 resolution display
PG Flash
PG Flash allows you to create repeatable custom tests on your PC and then uploaded to any DV2T Viscometer or DV3T Rheometer.
PG Flash allows you to create repeatable custom tests on your PC! Once the program (up to 25 steps) is created, it can be downloaded to a supplied USB flash drive and then uploaded to any DV2T Viscometer or DV3T Rheometer.
-
FEATURES BENEFITS
Create repeatable custom tests with all of the built-in options on the DV3T
Extends the capabilities of the DV2T by enabling the creation of multiple step programs (up to 25 steps)
Create the program on the PC, download to a USB Flash Drive, then upload the program from the USB Flash Drive to the DV2T or DV3T.
-
COMPUTER REQUIREMENTS
Windows 2000, XP, Vista, Windows 7, Windows 8, Windows 10
500 MHz processor
256 MB RAM
USB port
1280×768 resolution display
Powder Flow Pro
Collect comprehensive flow data quickly and easily with the use of the supplied Powder Flow Pro software. Powder Flow Pro operates and controls the Powder Flow Tester and is included with purchase of the instrument.
Powder Flow Pro software allows operation and control of the Brookfield PFT Powder Flow Tester.
- FEATURES BENEFITS
Main screen provides choice of basic tests: Flow Function, Wall Friction, Time Consolidated Flow Function and Bulk Density
Stress data output screen captures “normal stress” and “shear stress” values and plots data in graphical format (calculates Mohr Circle Failure Loci).
Flow Function curves are automatically calculated and displayed at the end of each test with overlay capability for up to eight different sample tests.
Produces multiple graphs describing powder flow behavior:
Unconfined Failure Strength vs. Major Principal Consolidating Stress
Arching Dimension vs. Principal Consolidation Stress
Rat-hole Diameter vs. Powder Fill Level
Arching Dimension vs. Hopper Half Angle
-
COMPUTER REQUIREMENTS
Windows XP, Vista, Windows 7, Windows 8, Windows 10
2 GHz processor
1 GB RAM
One USB or RS-232 port
1024×768 resolution display
Rheo3000
The RST Rheometer can be programmed using Rheo3000 to control shear stress or shear rate. Data is saved in a SQL database for easy access by multiple users on a network. Multiple test programs can be used for complete characterization of material flow behavior: viscoelastic modulus, yield stress, viscosity flow curve, creep behavior and recovery.
FEATURES BENEFITS
Program by controlled stress or rate User-friendly design and interface Automate viscosity vs. temperature testing Store data fast and safe in a SQL database User management Audit trail to support 21 CFR requirement Quality control limits for pass/fail test Data In- and Export (txt, csv, xml …) Automate analysis of data collected Calculate yield and average viscosity Create flow curves and plot yield stress 8 supported languages (live changeable) COMPUTER REQUIREMENTS Windows 7, Windows 8, Windows 10 2 GHz processor 2 GB RAM One USB port; If using a temperature controller, an RS-232 port is also required 1280×800 resolution display with 128 MB of graphics memory
RheocalcT
When used with the Brookfield DV2T Viscometer or DV3T Rheometer, RheocalcT can analyze data, generate multiple plot overlays, print tabular data, run math models and perform other time-saving routines. Up to five comparison data sets can be plotted and saved.
- FEATURES BENEFITS
Wizards to guide you through the creation of common tests Yield Testing, alone, or in conjunction with other viscosity measurements Secure 21CFR features including multiple logins, access levels, digital signatures, and data storage in a password-protected database Looping functions for repetitive tasks Averaging of collected data by step or whole test Math models: Bingham, Casson, Casson NCA/CMA, Power Law, IPC Paste, Herschel-Bulkley, Thix Index
- MINIMUM SYSTEM REQUIREMENTS:
Windows XP, Vista, Windows 7, Windows 8, Windows 10 2 GHz processor 2 GB RAM One USB port; If using a temperature controller, an RS-232 port is also required 1280×800 resolution display with 128 MB of graphics memory
Rheovision
Specifically designed for sophisticated rheological analysis, RheoVision makes viscosity measurement under pressurized and temperature controlled conditions an easy task. Powerful scripting language provides simple to complex data collection programs including automatic calculation of yield stress using Bingham, Herschel-Bulkley, and Power Law equations.
- FEATURES BENEFITS
USB and RS232 connectivity
Multiple PVS units to PC communication controls.
Enhanced graphing capabilities
Easy calibration checks with auto-calculation of the torque multiplier and built-in linearity check
Use of a powerful Microsoft SQL database allows users to
Define product, fluids, customer, location and other specific parameters for samples and later search data on these same fields
Search tests by parameters and allow data and test parameters to link for easier full profile viewing
Instantaneous flow curves
Built in math modeling
User-friendly ramp wizard for quick API testing
Seal history tracking feature
- APPLICATIONS
Fracturing Fluids
Petroleum Products
Drilling Muds
Black Liquor
Volatile Chemicals
- COMPUTER REQUIREMENTS
Windows XP, Vista, Windows 7, Windows 8, Windows 10
2.8 GHz processor
2 GB RAM
One USB or RS-232 port
1280×800 resolution display with 128 MB of graphics memory
TexturePro CT
Take control of your CT3 Texture Analyzer with this powerful, easy-to-use software! Collect data and perform detailed data analysis with real time graphic plotting during the test. Easily create custom reports and graphs right from the menu screen.
-
FEATURES BENEFITS
Easily select test parameters
Database file structure for easy-to-manage files
Sample identification set-up screen helps new operators quickly get started; test method setup defines a variety of parameters
Intuitive set up for test methods and database file structures in a single window
Data is captured as a graph and stored in tabular database format
Advanced data analysis with built-in parameter calculations such as springiness, chewiness, hardness and much more!
Evaluate mean and standard deviation of each result parameter for up to 30 samples
Secure 21CFR features – including multiple logins, access levels, digital signatures and data storage in a password-protected database.
- COMPUTER REQUIREMENTS
Windows XP, Vista, Windows 7 (32 or 64-bit), Windows 8, Windows 10
2 GHz processor
1 GB RAM
One USB or RS-232 port
800×600 resolution display
Wingather SQ
When used with the DV1 Viscometer, Wingather SQ software provides an easy way to gather data and plot graphs while creating permanent test records.
-
FEATURES BENEFITS
Multiple test modes to enhance data collection
Automatic sample numbering
Follow up events for automatic printing or analysis
Math models: Bingham, Casson, Casson NCA/CMA, Power Law, IPC Paste, Herschel-Bulkley, Thix Index
Data graphing of up to 20 data sets concurrently
Plot data available: % Torque, RPM, Viscosity, Shear Rate, Shear Stress, Temperature, Time
Data export to spread sheet format (Excel®)
DATA COLLECTION MODES
Timed Stop: Data points are continuously taken at the operator defined time interval
Timed Torque: Data points are continuously taken at operator defined time interval until the operator defined % torque value is reached
Spring Relax: Data points are continuously taken at operator defined time interval as the spindle unwinds in a sample
Vari-Speed: A data point is taken when the operator changes viscometer speed
Manual: A data point is taken upon a user button click
Collect All Data: All incoming data from the viscometer is collected
- COMPUTER REQUIREMENTS
Windows XP, Vista, Windows 7, Windows 8, Windows 10
2 GHz processor
2 GB RAM
One USB port
1280×800 resolution display with 128 MB of graphics memory
| 5 |
|
0 |
| 4 |
|
0 |
| 3 |
|
0 |
| 2 |
|
0 |
| 1 |
|
0 |
Related Products
- Product Code: Qnix 4600
QNix® 4600 – The coating thickness gaugeThe QNix® 4600 is a first-class measuring device that can easily keep up with its test objects thanks to its high speed of over 100 measurements per minute. The handy and ergonomic design of the device makes it the ideal choice for vehicle evaluation and secures it a pole position in terms of performance and ease of use. The practical one-button operati..
NHG268 gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with the standards of ASTM D523, ASTM D2457. NHG268 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source. NHG268 gloss meter can test material with a high gloss (0-2000Gu), and universally applicable..
NHG268 tri angle touch screen gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with the standards of ASTM D523, ASTM D2457. NHG268 touchscreen glossmeter conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source. NHG268 touch screen gloss meter 2000gu can test..





Reviews
There are no reviews yet.